Scanning Features
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a label, when in On
Line or Serial On Line mode. The range for this setting is from 1 to 255 seconds in 1-second
increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20
3. Go to
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
This completes the procedure. See
Table 38. Aiming Duration Time Setting Examples
STEP
ACTION
1
Desired Setting
2
Pad leading zero(es)
3
4
Scan Three Characters From
5
Appendix E, Keypad
6
Product Reference Guide
= 020, etc.
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
page 87
Programming Mode.
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
Mode.
1 Second
001
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT AIMING DURATION TIME SETTING
'0' , '0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix E, Keypad
for some examples of how to set this feature.
Table 38
EXAMPLES
90 Sec. (1.5 min.)
180 Sec. (3 min.) 255 Seconds (4.25 min.)
090
'0' , '9' and '0'
'1' , '8' and '0'
References
, that represent the
180
255
'2' , '5' and '5'
271