7
SYSLOG_PLUGOUT_SPS0
8
SYSLOG_PLUGOUT_SPS1
9
SYSLOG_PLUGOUT_DISK
10
SYSLOG_PLUGOUT_PORT
11
SYSLOG_PLUGIN_OK_SIM0
12
SYSLOG_PLUGIN_OK_SIM1
13
SYSLOG_PLUGIN_FAN0
14
SYSLOG_PLUGIN_FAN1
15
SYSLOG_PLUGIN_SPS0
16
SYSLOG_PLUGIN_SPS1
17
SYSLOG_POWER_BTN
18
SYSLOG_PHY_ERR_CNT
19
SYSLOG_PWROK_SPS0
20
SYSLOG_PWROK_SPS1
21
SYSLOG_NOT_PWROK_SPS0
22
SYSLOG_NOT_PWROK_SPS1
23
SYSLOG_ACOK_SPS0
24
SYSLOG_ACOK_SPS1
46
Sun Storage J4200/J4400 Array System Overview • June 2009
Power Supply 0 was removed.
Power Supply 1 was removed.
Disk 1 was removed.
SAS port 1 is down.
SIM 0 is enabled.
SIM 1 is enabled.
Fan 0 is present.
Fan 1 is present.
Power 0 is present.
Power 1 is present.
Front panel button is pressed
to mute alarm.
PHY error count exceeds
threshold value.
Power supply 0 has power.
Power supply 1 has power.
Power supply 0 has failed.
Power supply 1 has failed.
Power supply 0 is OK.
Power Supply 1 is OK.
J4200 only. System is in a
degraded mode. Reinstall
Power Supply 0 to ensure
a high degree of fault
tolerance.
System is in a degraded
mode. Reinstall Power
Supply 1 to ensure a high
degree of fault tolerance.
Check the connection to
SAS port 1.
The drive slot or SAS port
is unstable. Check disk
status and SAS cable
connections.
Check the connection
between the power cord
and Power Supply 0.
Check the connection
between the power cord
and Power Supply 1.
J4400 only.
J4400 only.
Need help?
Do you have a question about the J4200 and is the answer not in the manual?
Questions and answers