Chapter 3
Serial Configuration
User Outputs Commands
Beeper
Format: <Kubeeper status,beeper volume,beeper speed>
beeper status:
0 = Disabled
1 = On Good
2 = On Noread
Example: To enable the beeper for On Noread and set the beeper volume to
Level 5, enter <Ku2,4>.
Relay Driver
Format: <Kvrelay driver>
relay driver:
0 = Good Match
1 = Mismatch
Example: To change Relay Driver to Noread, enter <Kv2>.
New Master Pin
Format: <Kzstatus>
status:
0 = Disabled
Example: To enable New Master Pin, enter <Kz1>.
Laser On/Off
Format: <KCstatus>
status:
0 = Disabled
Example: To enable Laser On/Off, enter <KC1>.
3-14
MS-3000 Single Head Decoder User's Manual
beeper volume:
beeper speed:
0 = Level 1
0 = Fast
1 = Level 2
1 = Slow
2 = Level 3
3 = Level 4
4 = Level 5
2 = Noread
3 = Mismatch or Noread
1 = Enabled
1 = Enabled