Supplementals
Default:
Disabled
Options: Disabled, Enabled, Required
Note: Narrow Margins must be enabled if the gap between the standard code and
the supplemental code is between 5:1 and 10:1 (in relation to narrow-bar-width).
Allows the decoder to read supplemental bar code data that has been
appended to the standard UPC or EAN codes.
When set to Required, the decoder treats the supplemental data and the
bar code label as a single label. Also, supplemental data must be found or a
noread will result.
When set to Enabled, the decoder treats the supplemental data and the bar
code label as separate labels.
Separator
Default:
Enabled
Options: Enabled, Disabled
Allows you to insert a character between the standard UPC or EAN code
and the supplemental code.
Separator (character)
Default:
, (comma)
Options: Any ASCII character.
Allows you to change the separator character from a comma to a new
value.