User Outputs Menu
The User Outputs menu allows you to configure the decoder's output.
User Outputs
Beeper
Beeper
Status
Volume
On Good
Level 4
–
–
On Noread
Level 5
–
–
Disabled
Level 1
–
–
Level 2
–
Level 3
–
Laser On/Off
Reverse
Video
Disabled
–
Enabled
–
Disabled
–
Enabled
–
Serial command Echo
Beep on serial Command
Disabled
–
–
Enabled
–
–
* Divide the number entered on the command line by 100 for time in seconds.
Figure 2-6 User Outputs Menu Structure
Beeper
Default:
On Good
Options: On Good, On Noread, Disabled
A beep is emitted either after each good read of a bar code label, after each
noread, or not at all, according to the setting.
Note: The beep period will be short for triggered modes where a new trigger
occurs immediately or the output is delayed to the end of the read cycle on edge
and serial triggers.
Beeper Volume
Default:
Level 4
Options: Level 4, Level 5, Level 1, Level 2, Level 3
MS-3000 Single Head Decoder User's Manual
User Outputs Menu
Bold text represents default settings.
–
Beeper
Full Screens
Relay Driver
Speed
Enabled
Mismatch or
–
–
Noread
Disabled
Fast
–
–
Good Match
–
Slow
–
Mismatch
–
Noread
–
Good/Bad
Good/Bad
Pulse Width*
Polarity
50 ms
Positive
–
–
User Definable
Negative
–
–
(0 to 255)
Disabled
Enabled
New Master
Pin
Disabled
–
Enabled
–
Command
Start Character
<
–
User Definable
–
(ASCII char.)
2-29
Need help?