Chapter 2
Menu Configuration
Large Intercharacter Gap
Default:
Disabled
Options: Disabled, Enabled
Allows the decoder to read labels with gaps between bar code characters
exceeding three times the narrow element width.
Fixed Code Length
Default:
Disabled
Options: Disabled, Enabled
Used to increase data integrity by ensuring that only one label length will be
accepted.
Code Length
Default:
10
Options: 1 to 31
Note: Fixed Code Length
effect.
Allows you to specify the exact number of characters that the decoder will
recognize (this does not include start and stop). The decoder will ignore any
code not having the specified length.
Codabar
Status
Default:
Disabled
Options: Disabled, Enabled
Start & Stop Match
Default:
Enabled
Options: Enabled, Disabled
Requires the Codabar start and stop characters (a, b, c, or d) to match
before a valid read can occur.
Start & Stop Output
Default:
Enabled
Options: Enabled, Disabled
Allows the start and stop characters to be transmitted with bar code data.
2-24
MS-3000 Single Head Decoder User's Manual
(page
2-24) must be enabled for Code Length to take
Need help?
Do you have a question about the MS-3000 and is the answer not in the manual?