I 2 of 5
Format: <Krstatus,check digit status,check digit output status,code length
#1,code length #2>
status:
check digit status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
code length #1:
code length #2:
Zero or any even number
Zero or any even number from 2 to 30. Default
from 2 to 30. Default is 10.
is 6
Example: To enable I 2 of 5 and to set Fixed Code Length #1 to 8 and Fixed
Code Length #2 to 4, enter <Kr1,,,8,4> or <Kr1,0,0,8,4>.
UPC/EAN
Format: <Ksstatus,EAN status,supplementals status,separator
status,separator character>
status:
EAN status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
(UPC must also be enabled)
separator status:
separator character:
0 = Disabled
Any ASCII character (except NUL). Default is a
comma (,).
1 = Enabled
Example: To enable UPC and EAN, change supplementals to required, and
change separator character to a dash (–), enter <Ks1,1,2,1,–> or
<Ks1,1,2,,–>.
Code 128
Format: <Ktstatus,fixed code length status,code length>
status:
fixed code length status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
Example: To enable Code 128, enable Fixed Code Length, and set Code
Length to 9, enter <Kt1,1,9>.
Code Types Status Request
Format: <KW?>
Returns status of each command in the group.
MS-3000 Single Head Decoder User's Manual
Code Types Commands
check digit output status:
0 = Disabled
1 = Enabled
supplementals status:
0 = Disabled
1 = Enabled
2 = Required
code length:
Any number from 1
to 31.Default is 10.
3-13