Chapter 3
Serial Configuration

Code Types Commands

Narrow Margins
Format: <Kostatus>
status:
0 = Disabled
Example: To enable Narrow Margins, enter <Ko1>.
Code 39
Format: <Kpstatus,check digit status,check digit output,large interchar.
gap,fixed code length,code length>
status:
0 = Disabled
1 = Enabled
large interchar.
gap status:
0 = Disabled
1 = Enabled
Example: To set Fixed Code Length to 30, enter <Kp,,,,1,30> or
<Kp1,0,0,0,1,30>.
Codabar
Format: <Kqstatus,start & stop match,start & stop output,large interchar.
gap,fixed code length,code length>
status:
0 = Disabled
1 = Enabled
large interchar. gap
status:
0 = Disabled
1 = Enabled
Example: To enable Codabar and set Fixed Code Length to 9, enter
<Kq1,,,,1,9> or <Kq1,1,1,0,1,9>.
3-12
MS-3000 Single Head Decoder User's Manual
1 = Enabled
check digit status:
check digit output status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
fixed code length status:
code length:
0 = Disabled
Any number from 1 to 31.
Default is 10.
1 = Enabled
start & stop match status:
start & stop output status:
0 = Disabled
0 = Disabled
1 = Enabled
1 = Enabled
fixed code length status:
code length:
0 = Disabled
Any number from 1 to 31.
Default is 10.
1 = Enabled