Adjusting The Overlap Of The Sensor Flag - Toshiba e-Studio3511 Service Handbook

Toshiba e-studio multifunctional digital color systems
Hide thumbs Also See for e-Studio3511:
Table of Contents

Advertisement

3.13.3 Adjusting the overlap of the sensor flag

If the overlap between the sensor and the flag is wrong for some reason, perform the following adjustment.
(1)
Remove the processing tray unit.
(2)
Loosen the mounting screw of the front/rear
jogging plate adjusting plate; then, move the
adjusting plate to the left and the right.
(3) Tighten the screw so that the overlap between
the flag of the front/rear jogging rack plate and
the sensor is 1.5 mm to 2.0 mm.
November 2003 © TOSHIBA TEC
Jogging plate
adjusting plate
Screw
Adjusting plate
Fig. 3-1308
Sensor
1.5 mm to 2.0 mm
Fig. 3-1309
3 - 73
e-STUDIO3511/4511 ADJUSTMENT
Jogging plate
Screw
Adjusting plate
adjusting plate
Sensor flag

Advertisement