(4)
Measure the jogging width (standard at 317
mm).
(5)
Remove the processing tray.
(6)
Loosen the screw on the home position
sensor plate at the front.
(7)
Adjust the position of the front jogging plate
home position sensor (S6) with reference to
the index.
EX. 1
If the width is 319 mm in step (2), the
difference from the standard is +2 mm, it
requires relocation of the sensor [3] in the
direction of arrow A by 2 mm.
EX. 2
If the width is 316 mm in step (2), the
difference from the standard is -1 mm; it
requires relocation of the sensor [3] in the
direction of arrow B by 1 mm.
November 2003 © TOSHIBA TEC
Fig. 3-1304
A
Fig. 3-1305
3 - 71
e-STUDIO3511/4511 ADJUSTMENT
Home position
Screw
sensor plate
Sensor
B