Toshiba e-Studio3511 Service Handbook page 245

Toshiba e-studio multifunctional digital color systems
Hide thumbs Also See for e-Studio3511:
Table of Contents

Advertisement

(4)
Loosen 2 doctor blade fixing screws. Insert
the gauge "0.55" of the doctor-sleeve jig
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
(5)
Insert the gauge "0.50" of the doctor-sleeve
jig into the gap between the developer
sleeve and doctor blade and make sure that
the gauge can move smoothly in the front/
rear direction. In addition, confirm that the
gauge "0.60" cannot be inserted into the
gap.
Notes:
1. When confirming and adjusting the gap between the developer sleeve and the doctor blade, insert
the gauges into the gap after rotating the developer sleeve so that its marking faces the doctor
blade.
2. While reattaching the color developer unit cover, set the latches securely.
November 2003 © TOSHIBA TEC
Developer sleeve
Doctor blade
Doctor-sleeve
jig
Fig. 3-1107
Developer sleeve
Doctor-sleeve
jig
Fig. 3-1108
3 - 55
e-STUDIO3511/4511 ADJUSTMENT