Toshiba e-Studio3511 Service Handbook page 63

Toshiba e-studio multifunctional digital color systems
Hide thumbs Also See for e-Studio3511:
Table of Contents

Advertisement

Classifi-
Code
cation
338
Image
Color developer bias DC (-)
control
calibration voltage 1 (low)
339
Image
Color developer bias DC (-)
control
calibration voltage 2 (high)
340
Scanner
Reproduction ratio adjust-
ment of secondary scanning
direction (scanner section)
354
RADF
Adjustment of
RADF paper
alignment
355
356
RADF
Automatic adjustment of
RADF sensor and EEPROM
initialization
357
RADF
Fine adjustment of RADF
transport speed
358
RADF
RADF sideways deviation
adjustment
359
Scanner
Carriage position adjustment
during scanning from RADF
360
363
Scanner
Data transfer of
characteristic value of
scanner / SYS board -> SLG
board
364
Scanner
Data transfer of
characteristic value of
scanner / SLG board -> SYS
board
365
RADF
RADF leading
edge position
adjustment
366
November 2003 © TOSHIBA TEC
Adjustment mode (05)
Default
Func-
Items
<Acceptable
tion
value>
ALL
<85-115>
ALL
<810-990>
ALL
<0-255>
for single-
ALL
sided
<0-20>
original
for double
ALL
sided
<0-20>
original
ALL
ALL
<0-100>
ALL
<0-255>
ALL
(black)
<0-255>
ALL
(color)
<0-255>
SCN
SCN
for single-
ALL
sided
<0-100>
original
for double
ALL
sided
<0-100>
original
2 - 43
04/10
RAM
Contents
100
M
Transformer output calibration of the
color developer bias. When replacing
900
M
the high-voltage transformer, the
values listed in attached data sheet
are entered. (Unit: V)
127
SYS
When the value increases by "1", the
reproduction ratio in the secondary
scanning direction (vertical to paper
feeding direction) increases by
approx. 0.223%.
10
SYS
When the value increases by "1", the
aligning amount increases by approx.
0.5mm.
10
SYS
-
SYS
Performs the adjustment and
initialization when the RADF board or
RADF sensor is replaced.
50
SYS
When the value increases by "1", the
reproduction ratio of the secondary
scanning direction on original (fed
from the RADF) increases by approx.
0.1%.
128
SYS
When the value increases by "1", the
image of original fed from the RADF
shifts toward the rear side of paper
by approx. 0.0423mm.
128
SYS
When the value increases by "1", the
carriage position shifts by approx. 0.1
128
SYS
mm toward the exit side when using
the RADF.
-
SYS
Transfers the characteristic values of
the scanner (shading correction
factor / RGB color correction /
reproduction ratio color aberration
correction) from the NVRAM of the
SYS board to the NVRAM of the SLG
board.
-
SYS
Transfers the characteristic values of
the scanner (shading correction
factor / RGB color correction /
reproduction ratio color aberration
correction) from the NVRAM of the
SLG board to the NVRAM of the SYS
board.
50
SYS
When the value increases by "1", the
copied image of original fed from the
RADF shifts toward the trailing edge
50
SYS
of paper by approx. 0.1mm.
e-STUDIO3511/4511 ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
1
1
1
1
1
6
1
1
1
1
6
6
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio4511

Table of Contents