KYMCO Downtown 200i Service Manual page 50

Hide thumbs Also See for Downtown 200i:
Table of Contents

Advertisement

4. LUBRICATION SYSTEM
Remove two oil pump mounting bolts and the oil
pump.
OIL PUMP INSTALLATION
Install the oil pump into the crankcase.
Install the oil pump with the arrow on the
pump body facing up and fill the oil pump
with engine oil before installation.
After the oil pump is installed, tighten the two
mounting bolts.
Install the pump driven gear and drive chain by
aligning the pump driven gear with the cutout in
the pump shaft.
Install and tighten the pump driven gear bolts.
Install the oil separator cover and tighten the bolts.
Install the starter idle gear and starter clutch.
Install the gasket and dowel pins.
Install the right crankcase cover and tighten the
twelve bolts.
Torque: 1.2 kg-m
Diagonally tighten the bolts in 2~3 times.
DOWNTOWN 200i
Arrow Mark
Pump Shaft
Oil Separator Cover
Starter Idle Gear
Dowel Pin
4-6