Preamble
Preamble Status
Useful for identifying and controlling incoming data. For example, defining
Usage:
the preamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Defines a one to four character data string that can be added to the front of
Definition:
the decoded data.
<K141,status,preamble character(s)>
Serial Cmd:
Default:
Disabled
Options:
0 = Disabled
Preamble Characters
<K141,status,preamble
Serial Cmd:
Default:
^M
To enter control characters within a serial command, hold down the Ctrl
Options:
key while typing the desired character.
Example:
Important: The ASCII characters <, >, and
For <:
<K141h,,3C>
For >:
<K141h,,3E>
For
:
,
<K141h,,2C>
See
ASCII Character Entry Modifier
enter ASCII characters as hex values.
MINI Hawk High Performance Imager User's Manual
corresponds to:
carriage
<K141,1,CNTL-m>
on page 3-32 for a detailed explanation of how to
1 = Enabled (within any protocol)
character(s)>
return.
to enter the control character ^M.
can only be entered as hex pairs:
,
Communications
3-33