DataBar Limited (RSS Limited)
Note: DataBar Limited was previously known as "RSS Limited".
DataBar Limited is designed to be read by laser and CCD readers. It is
Usage:
not recommended for omnidirectional slot scanners.
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
Definition:
<K483,status>
Serial Cmd:
Default:
Disabled
Options:
0 = Disabled
DataBar-14 (RSS-14)
Note: DataBar-14 was previously known as "RSS-14".
Used in the grocery, retail, and prescription drug industries where 14-digit
Usage:
EAN item identification may be needed.
DataBar-14 is a fixed symbol length symbology that encodes 14 digits,
Definition:
including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be
stacked in two rows, it can read omnidirectionally if printed in full height, or
horizontally if height-truncated for small marking.
<K482,status>
Serial Cmd:
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (non-stacked)
2 = Enabled (stacked; decode both stacked and non-stacked)
Note: Where appropriate, use 1 (non-stacked) for better performance over
2 (stacked; decode both stacked and non-stacked).
MINI Hawk High Performance Imager User's Manual
1 = Enabled