Trigger Mode and Filter Duration
Leading Edge Trigger Filter
Used to ignore spurious triggers when Trigger Mode is set to External
Usage:
Edge or External Level.
To consider a change in state on the trigger input, the level must be stable
Definition:
for the trigger filter duration. In an edge mode, the imager will trigger a read
cycle if the active state has been uninterrupted for the entire trigger filter
duration. In a level mode, the leading edge is filtered such that on an active
edge, the state must be held interrupted for the trigger filter duration before
a trigger will occur.
<K200,trigger
Serial Cmd:
Default:
313
1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
Options:
Trailing Edge Trigger Filter
Used to ignore spurious triggers when Trigger Mode is set to External
Usage:
Edge or External Level.
To consider a change in state on the trigger input, the level must be stable
Definition:
for the trigger filter duration. In an edge mode, the imager will trigger a read
cycle if the active state has been uninterrupted for the entire trigger filter
duration. In a level mode, the trailing edge is filtered such that on the falling
edge, the state must be held for the trigger filter duration before the trigger
will be deemed inactive.
<K200,trigger mode,leading edge trigger
Serial Cmd:
Default:
313
1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
Options:
5-10
mode,leading edge trigger
(~10 ms)
(~10 ms)
filter,trailing edge trigger filter>
filter,trailing edge trigger