U L
For UL Listed systems this shall be programmed as "YES".
POINT ID FORMAT - RESTORES
Restores will be transmitted as follows:
SSSS 18 3XYZ GG CCC
where: SSSS = Account Number
18 = Point ID Format Code (Fixed)
3 = Indicates a new restore
XYZ = PID Event Code (Question 146)
GG = Group (partition number 01 - 08)
CCC = Zone (contact) number (Question 138)
FBI Superfast Format 4x3x1
1254 AZZR
where: A = Alarm type CS code (question #110) for this zone
ZZ = The zone CS code which identifies the zone number (defined in question 145
R = Restore code (question #111) defined for the alarm type programmed for this zone.
This format identifies a restore by the zone number and type of alarm.
STANDARD
Example:
123 R
where R = Restore code defined for the alarm type of this zone (question #111)
The value entered for the Zone CS code (question #145) will not be used.
EXTENDED
123 R
RRR Z
where: R = Restore Code (question #111) and Z is the zone CS code( question #145).
NOTE: This format can contain either three or four digits within the account number.
PARTIAL EXTENDED
123 R
RRR Z
where: R = Restore Code (question #111) and Z = Zone CS code (question #145).
The partial extended format transmits a single round signal for alarm conditions and
an expanded message for system conditions such as openings, closings, troubles etc.
NOTE: This format can contain either three or four digits within the account number.
4x2
1234 RZ
where: R = Restore code (question #111) and Z is the zone CS code (question #145).
Section 8 - LCD Keypad Programming Questions