Summary of Contents for FBII XL4612RM

  • Page 1 Previous Menu XL-31 OWNERS MANUAL :RE 8uRGURY INSTRUMENTS. INC..—---—...
  • Page 2 The keypad is the arming station for your security system. Theee are available keypads for your system: XL4612RM Metal plate keypad containing indicator lights for each of the 12 zones (areas of protection), This keypad can be flush mounted into your wall or surface mounted in a back box.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. KEYPAD LAYOUT XL4612RM ad XL4612SM 2. KEYPAD LAYOUT 7015 and 7005 3. KEYPAD CONVENTIONS 4. ARMING THE SYSTEM 5. DISARMING 6. ZONE RESET 7. STAY 8. INSTANT 9. INSTANT-STAY 10. BYPASS 11. UNBYPASS 12. USER DEFINITION 13.USERDELETION...
  • Page 4: Keypad Layout Xl4612Rm Ad Xl4612Sm

    KEYPAD LAYOUT XL4612RM and XL4612SM XL*12SM KEYPAD (&hl”d D.oo 1) ZONE STATUS INDICATORS - displays the current zone status as follows: ALARM Fastbknhng. BYPASS Slow btinkinglow intensity. TROUBLE Slow pulse NOTREADY SohdON READY 2) ARM/DISARM INDICATOR -indicates system armed or disarmed.
  • Page 5: Keypad Layout 7015 And 7005

    KEYPAD LAYOUT 7015 and 7005 MODEL 7015 LED KEYPAD The 7015 contains indicator tights for the zone status, and the 7005 keypad contains a two hne Enghsh language dsplay. 1) ZONE STATUS INDICATORS-Your protected location has been dwided info areas of protection known as zones. The zone indicators dsplay the current status of each zone as follows: ALARM Fast b[nking.
  • Page 6: Keypad Conventions

    — KEYPAD CONVENTIONS Throughout this users manual the following conventions are used to display the keystrokes required to perform the fundions. BYPASS Kq I&dd BYP- m kena~ l~dd ~STANT on INSTANT kwa~ STAY Kq l~dd STAY on kend. CODE Key I&d& CODE on ke~d WSER] dgfi u= ARMING THE SYSTEM...
  • Page 7 SYSTEM NOT READY If the system is not ready to be armed the READY indioator will be OFF. C)nLED based keypads the zone Indimtor Hghfs will display the zones whkh are currently not ready. The wndtion of each zone indicator refleofs the status of each zone as follows;...
  • Page 8: Disarming

    DISARMING Msarming the security system will deaaivate the system’s burglary function. This procedure can also be used to reset your system Hyou accidentally set off the system (example, opened a window while the system was armed, or excessive amount of smke activated fire protection system). DISARM PROCEDURE: Enter your user code.
  • Page 9: Zone Reset

    STAY PROCEDURE: STAY [USER] Depress the STAY key followed by your user @de. After a eumessful STAY arming the ARMED indicator will be ~i. In addtion, on the XL4612RM or XL4612SM keypad the RDY indicator will slowlybhnk.Onthe7015 keWad the STAY indicator will be tit. On the LCD keypad the following display will appear In the STAY mde only the external or perimeter burglary protection is active.
  • Page 10: Instant-Stay

    After the bypass (or unbypass) command has been accepted the unti will emit a continuous beep and bypassed zones appear in a slow btinking mode in the zone status area on the XL4612RM, XL4612SM or 7015 keypads. The 7005 LCD keypad displays the zone b~asaes as a samndary display after the SYSTEM READY or SYSTEM NOT READY as shown balow: If mutiple zones are bypassad then more than one display will appear.
  • Page 11: Unbypass

    A QUICK BYPASS command can also be programmed by your installer. If selected, then bypasses can be performed without entry of a user code. For example BYPASS 06 will bypass zone 6. Please conauk wtih your installer to determine whether this function is available on your system. 11.
  • Page 12: Userdeletion

    ~ g. USER DELETION Removal of users from the panel can be performed as follows; USER DELETION PROCEDURE: CODE [USER] [User number]# Where: CODE is the depression of the CODE key. [USER] Master usercode [User number] Represents theuser number being deleted (03-30) .Note: Master users (User number 1 or number 2) cannot be deleted.
  • Page 13: Doorstrike Usercode

    10:25PM (assume a user code of 4567) enter: # 345672025 NOTE: If the system clock needs to be reset, the indicator tights on the XL4612RM, XL4612SM or 7015 keypads will blink rapidly in succession every 30 seconds, The 7005 keypad will display a message.
  • Page 14: Set Auto-Arm Time

    SET AUTO-ARM TIME (#5) Another option selectable by your installer is auto arming, This feature means that the system can be programmed to arm at a preprogrammed time eve~ day. This will occur at the selected time if the system is not already armed. For example, if you have an 11:30 PM auto-arming time programmed and fall asleep without arming the system, the panel will automatically arm at 11:30.
  • Page 15: Installation Uyout

    28. lNsTAL~TloN LAYOUT Early warning fire detection is beef achieved by the installation of fire detection equipment the bcation as folfows; Typbl 3moke ~teotor hyoti BEDROOM 8EDR00M BEDROOM 1. mw. M--- 2. *1w to N.F.PA 974 -X B-1 .1 w=10. Preparation of an evacuation plan is of prime impotiance in tire prevention.
  • Page 16: System Testing

    SYSTEM TESTING This control unit was manufactured under rigid quafity standards. Maintenance is best peflormed by your installing company with trained service personnel. Installing Company: Telephone Numbec It is recommended that you test your systam onca a week using the following procedure: Note: lfyoursystem ismntiored...
  • Page 17: Fcc Statement

    CWUNICAmONS CO~SSION FEDERAL (FCC) STAWENT This equipmenthas hen tested to FCC requirementsand hea been found sccept~le for use. The FCC requires the following statement for your information. This equipment generates and uses ratio frequemy energy and i not installed and used properly, that is in etricf acmrdance wkh the manufacturer’s instructions may cause interference to radio and television reception.
  • Page 18: Limitations Statement

    WARNING LIMITAmONS ALARM SYS~M While this system is an advanced design security system, if does not offer guaranteed protection against burgla~, fire or other emergency. Any alarm aysfem, whether wmmercial or residential, is eubjecf to compmmlse or failure to warn for a variety of reasons. For example: Intruders may gain ameee through unprotected openings or have the technical sophistication to bypase an alarm sensor or disconnect an alarm warning device.
  • Page 19 Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas revered by the beams. They cannot detect motion or intrusion that takes place behind walls, ceifings, floors, closed doors, glass patitions, glass doors, or window.
  • Page 20 30.SUMMARY PROCEDURE SEQUENCE ARM SYSTEM [USER] STAY STAY [USER] INSTANT INSTANT [USER] INSTANT-STAY INSTANT-STAY [USER] OR STAY INSTANT USER BYPASS BYPASS [USER] [Zn] UNBYPASS BYPASS [Zn] If zone is already bypaaaad DISARM [USER] USERDEFINITION CODE [USER] [USER NUMBER] [USID] USERDELETION CODE [USER] [USER NUMBER] # KEYPAD AUXILIARY CONDlmONS...
  • Page 21: Warrann

    FIRE BURGLARY INSTRUMENTS ONE YEAR LIMITED WARRANW Fire BurglaryInstruments,a aubsidia~ of P~ay Co~ration, and P~ay tir~ration kadivisions. subsidiariesandaffih#ea ~Seller-),149 Eileen Way SyosaetNYl1791, warrantsis sacurii aquipmanl(Iha pmdti”) to be frae from def6cts in materials and workmanship one year from the date of original purchase, under normti use and servica.
  • Page 22: Owners Information

    OWNERS INFORMATION PERSONAL NAME ADDRESS: CIW, STATE, ZIP: TELEPHONE NUMBER: EMERGENCY NUMBERS CENTRAL STATION: FIRE DEPARTMENT POLICE DEPARTMENT NEIGHBOR: GAS/ELECTRiCCOMPANY DOCTOR: HOSPITAL: EMERGENCY SERVICEINFORMAnON AWRMINSTALLING COMPANY...

This manual is also suitable for:

Xl4612smXl-31 series

Table of Contents