XL-4, XL-4B, and XL-5 LCD Keypad Programming Manual
A value of 00 indicates that AC failure should be sent immediately, while a value of 15
indicates that AC loss should never be sent. Default value = 2 (30 minutes).
Exit Triggers
074 EXIT TRG
NNNNNNNN
Indicates whether any of the eight programmable voltage level output triggers will be
activated upon an exit condition. The position of the Y or N indicates the trigger number.
This trigger will be latched for the duration of the exit interval. When the relay module is
enabled in question 032, the position of the Y or N becomes the arming status for partitions 1
though 8 for corresponding relay 1 through 8. Default = NNNNNNNN.
The triggers are active high and go from 0 - 12 volts, 25mA maximum current.
The FORWARD (INSTANT) and BACKWARD (CODE) keys are used to position the cursor
to the desired position while the TOGGLE (0) key will change the Yes/No status of that
trigger. The first position represents trigger #1, the second position trigger #2, etc
Entrance Triggers
075 ENT TRG
NNNNNNNN
Indicates whether any of the eight programmable voltage level output triggers will be
activated upon an entrance condition. The position of the Y or N indicates the trigger
number. This trigger will be latched for the duration of the entrance interval. Default =
NNNNNNNN.
The triggers are active high and go from 0 to 12 volts, 25mA maximum current.
The FORWARD (INSTANT) and BACKWARD (CODE) keys are used to position the cursor
to the desired position while the TOGGLE (0) key will change the Yes/No status of that
trigger. The first position represents trigger #1, the second trigger #2, etc.
Triggers 7 and 8 should be set to N if relay module XL-4705 is enabled.
Cutoff Timer #1
076 TIMEOUT1 1MN
14 (00-15)
The control panel contains three different bell cutoff times that can be selected for the alarm
and trouble types. Enter the duration of timeout #1 in one minute intervals.
Cutoff Timer #2
077 TIMEOUT2 2MN
15 (00-15)
The control panel contains three different bell cutoff times that can be selected for the alarm
and trouble types. Enter the duration of timeout #2 in two minute intervals.
The cutoff timers are selected in the alarm and trouble type and relate to whichever relay is used
for that particular alarm or trouble type.
8–30
Version 4