New Features of Version 4
The following new features have been added to the system in Version 4:
Common keypad showing armed status - If selected, entering # 0 User Code # will change the
keypad to a status keypad and display the armed status of each partition (Question 53).
Auto arming by day by partition - If selected, the day and time can be set for auto arming of
each partition (Question 34).
Even zones can be defined as tampers for odd zones - If selected, all even zones will report a
tamper in the partition that the previous odd zone was enabled in. (Question 83).
A common partition – All zones considered as parts of a common partition are programmed to
partition 8.
2-Call Feature used in downloading the panel - To use this feature, dial the panel, let the
phone ring once and hang up. Redial the panel and the panel will answer on the first ring. All
remote features can be performed.
XL-4705 Relay Module - The XL-4705 relay module is now supported.