XL-4, XL-4B, and XL-5 LCD Keypad Programming Manual
For PID formats the code transmitted will be 402 with the new event indication.
Closing Code
088 CLOSE CODE
C
( 0 - F )
Indicates the reporting code for a closing. If the system is partitioned then the account
number transmitted to the Central station will depend on the partition where the closing
occurred. In addition if the transmission format selected includes the user code then the user
number will be included based on the transmission path defined in question 033.
For PID format the CLOSE code is 402 with the restore indication.
Clock Set Code
089 Clock CODE
0
( 0 - F )
This defines the code to be transmitted to the Central Station if any clock set change is
performed at the keypad. This signal will be transmitted based on the reporting path defined
in question 035.
If PID Format is selected then an event code of 625 will be transmitted.
Cancel Code
090 CANCEL CODE
F
(0 - F)
This code is transmitted to the Central Station if the system is disarmed after an alarm
condition. If the format supports 2 digits, the second digit will be the user ID that disarmed
the system. This signal will be transmitted based on the reporting path defined in question
091.
If PID Format is selected then an event code of 458 will be transmitted.
Cancel Path
091 CANCEL PATH
NONE
This indicates the CS transmission path for cancel codes. Press 0 to toggle through the
available choices:
CS#1 ONLY
CS#2 ONLY
CS#1 & CS#2
CS#1 BU CS#2
CS#2 BU CS#1
NONE
8–34
Primary Receiver Only
Secondary Receiver Only
Both Receivers always
CS#1 backed up by CS#2
CS#2 backed up by CS#1
No cancel transmissions