CS Test Code
092 CS TEST CODE
8
( 0 - F )
Indicates the reporting code for a system test. The specific type of system test (12 hour , 24
hour or weekly) and the time of system test are defined in questions 037 - 039. Test signals
will be transmitted based on the path defined in question 036. The system test code
represents the entire panel rather than a specific partition and the account numbers for
partition 1 will be used.
Enter a single digit for the system test code. In a 4x2 format this will represent the first digit
transmitted for system test. For PID format the event code is defined in the next question.
CS Test ID Code
093 TEST ID CODE
253
000 - 255
If the Central Station reporting format selected is Point ID then this will define the zone
identification to be transmitted to the CS. If PID Format is selected then an event code of
602 will be transmitted. If a 4x2 or extended format is used then this question will represent
the second digit of the transmission. The code needs to be entered in decimal format
(example 1 through 9 = 001 through 009, A=010, B=011, C=012, D=013, E=014, F=015).
AC Loss ID Code
094 AC ID CODE
250
000 - 255
If the Central Station reporting format selected is Point ID (PID) then this defines the zone
identification number to be transmitted to the CS. If PID Format is selected then an event
code of 301 will be transmitted. If a 4x2 or extended format is used then this question will
represent the second digit of the transmission. The code needs to be entered in decimal
format (example 1 through 9 = 001 through 009, A=010, B=011, C=012, D=013, E=014,
F=015).
Low Battery ID Code
095 LOW BATT ID
251 000 - 255
If the Central Station reporting format selected is Point ID then this defines the point ID
reporting condition to be reported to the CS for a low battery condition. If PID Format is
selected then an event code of 302 will be transmitted. If a 4x2 or extended format is used
then this question will represent the second digit of the transmission. The code needs to be
entered in decimal format (example 1 through 9 = 001 through 009, A=010, B=011, C=012,
D=013, E=014, F=015).
System Error ID Code
096 SYS ERR ID
254
000 - 255
If the Central Station reporting format selected is Point ID then this defines the id (zone) to
be transmitted to the CS upon sensing a system error. If PID Format is selected then an
event code of 300 will be transmitted.
If a 4x2 or extended format is used then this question will represent the second digit of the
transmission. The code needs to be entered in decimal format (example 1 through 9 = 001
through 009, A=010, B=011, C=012, D=013, E=014, F=015).