FBII XL-4 Programming Manual page 73

Lcd programming guide
Hide thumbs Also See for XL-4:
Table of Contents

Advertisement

STANDARD
Example:
123 Z
where: Z = Zone CS code
The value entered for the Alarm Type CS code will not be used. Enter the desired zone
CS code in decimal format. For example to transmit a code of 3 enter 003. If your
receiver supports reporting digits in hex, and you wish to transmit a hexadecimal code,
then enter the decimal equivalent (example B = 011).
EXTENDED
123 A
AAA Z
where: A = Alarm type CS Code (question #110) and Z is the zone CS code. If the condition
will initiate a trouble signal then the "A" will originate from the Trouble Type entered
in question #131.
NOTE: This format can contain either three or four digits within the account number.
Enter the desired zone CS code in decimal format. For example to transmit a 6 enter 006.
If your receiver supports reporting digits in hex, and you wish to transmit a hexadecimal
code, then enter the decimal equivalent (example B = 011).
PARTIAL EXTENDED
For Alarms
123 Z
where: Z = Zone CS code. The value entered for the Alarm Type CS code will not be used.
For Openings, Closings, Troubles etc.
123 A
AAA Z
where: A = Alarm type CS Code (question #110) and Z is the zone CS code. If the condition
will initiate a trouble signal then the "A" will originate from the Trouble Type entered
in question #131.
NOTE: This format can contain either three or four digits within the account number.
Enter the desired zone CS code in decimal format. For example to transmit a 6 enter 006.
If your receiver supports reporting digits in hex, and you wish to transmit a hexadecimal
code, then enter the decimal equivalent (example B = 011).
4x2
1234 AZ
where: A = Alarm type CS code (question #110), or trouble type code (question 131), and Z
is the zone CS code. Enter the desired zone CS code in decimal format. For example to
transmit a 6 enter 006. If your receiver supports reporting digits in hex, and you wish
to transmit a hexadecimal code, then enter the decimal equivalent (example B = 011).
FBI Superfast Format 4x3x1
1234 AZZA
where: A = Alarm type CS code (question #110), or Trouble Type code (question #131). The
desired zone CS code (displayed above as ZZ) should be entered in decimal. For
example, a desired zone code of 71 should be entered as 071. The control panel will
translate the zone number into its hex equivalent, and the English language printout
of the CP220 receiver will display the correct zone number in decimal format.
Section 8 - LCD Keypad Programming Questions
8–51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl-5Xl-4b

Table of Contents