FBII XL-4 Programming Manual page 46

Lcd programming guide
Hide thumbs Also See for XL-4:
Table of Contents

Advertisement

XL-4, XL-4B, and XL-5 LCD Keypad Programming Manual
U L
In UL Listed systems this option must be "NO".
Press the 0 key to toggle between the available choices.
Restores To Follow Loop
051 RES FOL LOOP
NO
Indicates whether all restore signals are to follow the loop or after bell cutoff. If NO then
restores occur after the bell cutoff period and the loop has returned to the normal condition,
or if the system is disarmed after alarm and the zone is not recycled. Default = NO.
If selecting this option then the action on abort (question 052) should be programmed for "no
abort".
U L
In UL Listed systems this option must be "NO".
Press the 0 key to toggle between the available choices.
Action On Abort
052 ACT ON ABORT
NO ABORT
Indicates the action to be taken on an abort. The options are:
ABORT CODE
STOP DIALING
NO ABORT
RESTORE
Press the 0 key to toggle between the available choices.
The abort action is system wide and will be used for all zones within all partitions.
Additional notes on the abort feature:
Only alarms caused by actual zones (not keypad emergency conditions) are abortable. Zones
must have an alarm type specifying a dial delay to be abortable (even if the dial delay time is
set to 0). If dial delay is set to NO in the alarm type then there is no capability to abort the
signal.
Zones are abortable until receipt of handshake All formats (except PID) will transmit the
abort action followed by the zone code. PID format will transmit the cancel code (406) and
the user number.
Multi-Partition Mode
053 CROSS PART
YES
This option enables an authorized user at one keypad to access other partitions within the
system through the # 0 command. Authorized users will be able to view the status of other
partitions and perform commands from the keypad. Press the 0 key to toggle between the
available choices.
8–24
Transmit the abort code instead of the alarm code
Stop the transmission, send nothing
No abort capability; send alarm code
Transmit the restore code instead of the alarm code
Version 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl-5Xl-4b