Setting The Set Frequency To Operate (Example: Performing Operation At 30Hz) - Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual

Fr-f700p series
Hide thumbs Also See for FR-F720P-0.75K to 110K:
Table of Contents

Advertisement

Selection of operation mode and
operation location

4.19.2 Setting the set frequency to operate (example: performing operation at 30Hz)

POINT
Operation panel (FR-DU07) is used to give both of frequency and start commands in PU operation.
Operation example Performing operation at 30Hz.
Operation
1. Screen at power-ON
The monitor display appears.
2. Operation mode setting
Press
to choose the PU operation mode.
3. Running frequency setting
Turn
to show the frequency "
want to set.
The frequency flickers for about 5s.
While the value is flickering, press
(If you do not press
display then returns to "
"Step 3" and set the frequency again. After the value flickered for
about 3s, the display returns to "
4. Start → acceleration → constant speed
Press
or
to start running.
The frequency on the display increases in the Pr. 7 Acceleration
time, and "
" (30.00Hz) appears.
To change the set frequency, perform the operation in above step 3. (Starting from the previously set frequency.)
5. Deceleration → Stop
Press
to stop.
The frequency on the display decreases in the Pr. 8 Deceleration
time, and the motor stops rotating with "
displayed.
214
Operation panel
" (30.00Hz) you
to set the frequency.
, the value flickers for about 5s and the
" (0.00Hz). At this time, return to
" (monitor display).
" (0.00Hz)
(FR-DU07)
PU indicator is lit.
Flicker
Frequency setting complete!!
···
After 3s, the monitor display appears.
/
Display
PU
EXT NET
Flickers for about 5s
Stop

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents