Operation Mode At Power-on (pr. 79, Pr. 340) - Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual

Fr-f700p series.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410

Advertisement

Selection of operation mode and
operation location

4.19.5 Operation mode at power-ON (Pr. 79, Pr. 340)

When power is switched ON or when power comes back on after instantaneous power failure, the inverter can be
started up in Network operation mode.
After the inverter has started up in the Network operation mode, parameter write and operation can be performed
from a program.
Set this mode for communication operation using the RS-485 terminals or communication option.
Parameter
Name
Number
79
Operation mode selection
*1
Communication startup
340
*2*3
mode selection
The above parameters can be changed during a stop in any operation mode.
*1
This parameter allows its setting to be changed in any operation mode even if "0 (initial value) or 1" is set in Pr. 77 Parameter write selection.
*2
This parameter allows its setting to be changed in any operation mode even if "0 (initial value)" is set in Pr. 77 Parameter write selection.
*3
The parameters can be set when Pr. 160 User group read selection = "0". However, the parameters can be set whenever the communication
option is connected. (Refer to page 201.).
(1) Specify operation mode at power-ON (Pr. 340)
⋅ Depending on the Pr. 79 and Pr. 340 settings, the operation mode at power-ON (reset) changes as described below.
Pr. 340
Pr. 79
Operation Mode at Power ON, Power
Setting
Setting
0
(initial
External operation mode
value)
1
PU operation mode
2
External operation mode
0
(initial
3, 4
External/PU combined operation mode
value)
6
External operation mode
External operation mode when X12 (MRS) signal ON
7
External operation mode when X12 (MRS) signal OFF
0
NET operation mode
1
PU operation mode
2
NET operation mode
1, 2
3, 4
External/PU combined operation mode
*1
6
NET operation mode
NET operation mode when X12 (MRS) signal ON
7
External operation mode when X12 (MRS) signal OFF
0
NET operation mode
1
PU operation mode
2
NET operation mode
10, 12
3, 4
External/PU combined operation mode
*1
6
NET operation mode
7
External operation mode
*1
The Pr. 340 setting "2" or "12" is mainly used for communication operation using the inverter RS-485 terminals. When a value other than "9999" (selection
of automatic restart after instantaneous power failure) is set in Pr. 57 Restart coasting time, the inverter will resume the same operation state which was in
before after power has been restored from an instantaneous power failure.
When Pr. 340 = "1, 10", a start command turns OFF if power failure has occurred and then restored during a start command is ON.
*2
The operation mode cannot be switched directly between the PU operation mode and Network operation mode.
*3
Operation mode can be changed between the PU operation mode and Network operation mode with
♦ Parameters referred to ♦
Pr. 57 Restart coasting time
Pr. 79 Operation mode selection
218
Initial
Setting
Value
Range
0
0 to 4, 6, 7
0
1, 2
0
10, 12
Restoration, Reset
Refer to page 162.
Refer to page 206.
Description
Select the operation mode. (Refer to page 208.)
As set in Pr. 79.
Started in network operation mode.
When the setting is "2", it will resume the pre-instantaneous power
failure operation mode after an instantaneous power failure occurs.
Started in network operation mode. Operation mode can be
changed between the PU operation mode and Network
operation mode from the operation panel. When the setting is
"12", it will resume the pre-instantaneous power failure operation
mode after an instantaneous power failure occurs.
Operation Mode Switching
Switching among the External, PU, and NET operation mode is
enabled
*2
Fixed to PU operation mode
Switching between the External and Net operation mode is enabled
Switching to PU operation mode is disabled
Operation mode switching is disabled
Switching among the External, PU, and NET operation mode is
enabled while running
Switching among the External, PU, and NET operation mode is
enabled
*2
Fixed to External operation mode (Forcibly switched to External
operation mode.)
Same as when Pr. 340 = "0"
Switching between the PU and NET operation mode is enabled
Same as when Pr. 340 = "0"
Fixed to NET operation mode
Same as when Pr. 340 = "0"
Switching between the PU and NET operation mode is enabled
while running
*3
Same as when Pr. 340 = "0"
key of the operation panel (FR-DU07) and X65 signal.
*3

Advertisement

Table of Contents

   Also See for Mitsubishi Electric FR-F720P-0.75K to 110K

   Related Content for Mitsubishi Electric FR-F720P-0.75K to 110K

Comments to this Manuals

Symbols: 0
Latest comments: