Fault Code Output Selection (Pr.76) - Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual

Fr-f700p series
Hide thumbs Also See for FR-F720P-0.75K to 110K:
Table of Contents

Advertisement

Operation setting at fault occurrence

4.14.2 Fault code output selection (Pr.76)

At fault occurrence, its description can be output as a 4-bit digital signal from the open collector output terminals.
The fault code can be read by a programmable controller, etc., and its corrective action can be shown on a
display, etc.
Parameter
Number
76
Fault code output selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 201)
⋅ By setting Pr. 76 to "1" or "2", the fault code can be output to the output terminals.
⋅ When the setting is "2", a fault code is output at only fault occurrence, and during normal operation, the terminals
output the signals assigned to Pr. 191 to Pr. 194 (output terminal function selection).
⋅ The following table indicates fault codes to be output. (0: output transistor OFF, 1: output transistor ON)
Operation Panel
Indication
(FR-DU07)
Normal *
E.OC1
E.OC2
E.OC3
E.OV1 to E.OV3
E.THM
E.THT
E.IPF
E.UVT
E.FIN
E. BE
E. GF
E.OHT
E.OLT
E.OPT
E.OP1
Other than the above
* When Pr. 76 = "2", the output terminals output the signals assigned to Pr. 191 to Pr. 194 .
CAUTION
⋅ When a value other than "0" is set in Pr.76
When a fault occurs, the output terminals SU, IPF, OL, FU output the signal in the above table, independently of the Pr. 191 to
Pr. 194 (output terminal function selection) settings. Please be careful when inverter control setting has been made with the output
signals of Pr. 191 to Pr. 194.
♦ Parameters referred to ♦
Pr. 191 to Pr. 194 (output terminal function selection)
174
Name
Initial Value
Output of Output Terminals
SU
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
Refer to page 140
Setting Range
0
1
0
2
IPF
OL
FU
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
1
1
Description
Without fault code output
With fault code output
(Refer to the following table)
Fault code output at fault occurrence
only (Refer to the following table)
Fault Code
0
0
1
1
0
2
1
3
0
4
1
5
0
6
1
7
0
8
1
9
0
A
1
B
0
C
1
D
0
E
0
E
1
F