Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual page 82

Fr-f700p series
Hide thumbs Also See for FR-F720P-0.75K to 110K:
Table of Contents

Advertisement

Function
Parameters
549
Protocol selection
NET mode operation command
550
source selection
PU mode operation command source
551
selection
553
PID deviation limit
554
PID signal operation selection
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
563
Energization time carrying-over times
564
Operating time carrying-over times
571
Holding time at a start
575
Output interruption detection time
576
Output interruption detection level
577
Output interruption cancel level
611
Acceleration time at a restart
653
Speed smoothing control
654
Speed smoothing cutoff frequency
Regeneration avoidance frequency
665
gain
779
Operation frequency during
communication error
791
Acceleration time in low-speed range
792
Deceleration time in low-speed range
Pulse increment setting for output
799
power
800
Control method selection
820
Speed control P gain 1
821
Speed control integral time 1
867
AM output filter
870
Speed detection hysteresis
872
Input phase loss protection selection
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance at deceleration
884
detection sensitivity
885
Regeneration avoidance
compensation frequency limit value
886
Regeneration avoidance voltage gain
Name
0, 1
0, 1, 9999
1, 2
0 to 100.0%, 9999
0 to 3, 10 to 13
0.1 to 1.0s
0.0 to 20.0s
0 to 500A/0 to 3600A
(0 to 65535)
(0 to 65535)
0.0 to 10.0s, 9999
0 to 3600s, 9999
0 to 400Hz
900 to 1100%
0 to 3600s, 9999
0 to 200%
0 to 120Hz
0 to 200%
0 to 400Hz, 9999
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
9, 20
0 to 1000%
0 to 20s
0 to 5s
0 to 5Hz
0, 1
0, 1, 2
300 to 800V
0 to 5
0 to 30Hz, 9999
0 to 200%
Minimum
Setting Range
Setting
Increments
1
1
1
0.1%
1
0.1s
0.1s
0.01/0.1A
*2
1
1
0.1s
0.1s
0.01Hz
0.1%
0.1s
0.1%
0.01Hz
0.1%
0.01Hz
0.1/0.01s
0.1/0.01s
0.1
1
1%
0.001s
0.01s
0.01Hz
1
1
0.1V
1
0.01Hz
0.1%
Parameter list
Refer
Initial
Customer
to
Value
Setting
Page
0
247
9999
219
2
219
9999
261
0
261
1s
286
0s
286
Rated
inverter
286
*2
current
0
152
0
152
9999
113
1s
261
0Hz
261
1000%
261
5/15s
162
*2
0
184
20Hz
184
100
279
9999
231
9999
109
9999
109
1kWh
149
20
82
25%
84
0.333s
84
0.01s
157
0Hz
144
0
175
0
279
380V/
279
760VDC
*5
0
279
6Hz
279
100%
279
71
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents