Du/pu Monitor Display Selection (pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891); Du/pu Monitor Display Selection - Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual

Fr-f700p series.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410

Advertisement

Monitor display and monitor output signal

4.12.2 DU/PU monitor display selection

(Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
The monitor to be displayed on the main screen of the operation panel (FR-DU07)/parameter unit (FR-PU04/FR-
PU07) can be selected.
In addition, signals to be output from the terminal FM (pulse train output) and AM (analog voltage output) can be
selected.
Parameter
Name
Number
DU/PU main display data
52*
selection
FM terminal function
54*
selection
AM terminal function
158*
selection
170
Watt-hour meter clear
171
Operation hour meter clear
Monitor decimal digits
268 *
selection
Energization time
563
carrying-over times
Operating time carrying-
564
over times
Cumulative power monitor
891*
digit shifted times
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 201)
* This parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77
Parameter write selection.
(1) Monitor description list (Pr. 52)
⋅ Set the monitor to be displayed on the operation panel (FR-DU07) and parameter unit (FR-PU04/FR-PU07) in Pr.
52 DU/PU main display data selection.
⋅ Set the monitor to be output to the terminal FM(pulse train output) in Pr. 54 FM terminal function selection.
⋅ Set the monitor to be output to the terminal AM (analog output (0 to 10VDC voltage output)) in Pr. 158 AM terminal
function selection.
⋅ Refer to the following table and set the monitor to be displayed. (The signals marked × cannot be selected for
monitoring)
Types of Monitor
Increments
Output frequency
0.01Hz
0.01A/0.1A
Output current
*7
*5
Output voltage
0.1V
Fault display
Frequency setting
0.01Hz
value
152
Initial Value
0
(output
frequency)
1
(output
frequency)
9999
9999
9999
0
0
9999
Pr. 52 Parameter
Pr. 54 (FM)
Setting Value
Pr. 158 (AM)
Parameter
PU main
Setting
DU LED
monitor
Value
0/100
1
0/100
2
0/100
3
×
0/100
5
5
*1
Setting Range
0, 5, 6, 8 to 14,
Select the monitor to be displayed on the
17, 20, 23 to 25,
operation panel and parameter unit.
50 to 57, 100
Refer to the following table for monitor description.
Select the monitor output to terminal FM.
1 to 3, 5, 6,
8 to 14, 17, 21,
24, 50, 52, 53
Select the monitor output to terminal AM.
0
Set "0" to clear the watt-hour meter monitor.
Sets the maximum value for the monitoring from
10
communication to 9999kWh.
Sets the maximum value for the monitoring from
9999
communication to 65535kWh.
Set "0" to clear the operation time monitor.
0, 9999
Setting "9999" has no effect.
0
Displayed as integral value.
1
Displayed in 0.1 increments.
9999
No function
0 to 65535
Displays the numbers of cumulative energization
(reading only)
time monitor exceeded 65535h. Reading only
0 to 65535
Displays the numbers of operation time monitor
(reading only)
exceeded 65535h. Reading only
Set the number of times to shift the cumulative
0 to 4
power monitor digit.
Clamps the monitor value at maximum.
No shift
9999
Clears the monitor value when it exceeds the
maximum value.
Full-scale value
of the terminal
FM and AM
Displays the inverter output frequency
Pr. 55
Displays the inverter output current
Pr. 56
effective value
200V class:
400V
Displays the inverter output voltage
400V class:
800V
Displays 8 past faults individually
Pr. 55
Displays the set frequency
Description
Description

Advertisement

Table of Contents

   Also See for Mitsubishi Electric FR-F720P-0.75K to 110K

   Related Content for Mitsubishi Electric FR-F720P-0.75K to 110K

Comments to this Manuals

Symbols: 0
Latest comments: