Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual page 358

Fr-f700p series
Hide thumbs Also See for FR-F720P-0.75K to 110K:
Table of Contents

Advertisement

•400V class
Type FR-F740P-
K
Applicable motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Rated voltage
*5
Rated input AC voltage/
frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
Without
Power supply
DC
system capacity
reactor
(kVA)
With DC
*6
reactor
Protective structure
(JEM 1030)
*8
Cooling system
Approx. mass (kg)
Type FR-F740P-
K
Applicable motor capacity
(kW)
*1
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Rated voltage
*5
Rated input AC voltage/
frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
Without DC
Power supply
reactor
system capacity
With DC
(kVA)
*6
reactor
Protective structure
(JEM 1030)
*8
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor. To use a
dedicated IPM motor, refer to page 359 and 360.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter
output current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated
duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting
range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*7
When the hook of the inverter front cover is cut off for installation of the plug-in option, protective structure of the inverter changes to an open
type (IP00).
*8
FR-DU07: IP40 (except for the PU connector)
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
*1
1.6
2.7
3.7
5.8
2.1
3.5
4.8
7.6
(1.8)
(3.0)
(4.1)
(6.4)
120% 60s, 150% 3s (inverse-time characteristics)
2.1
4.0
4.8
8.0
1.2
2.6
3.3
5.0
Enclosed type (IP20)
Self-cooling
3.5
3.5
3.5
3.5
75
90
110
132 160 185 220 250 280 315 355 400 450 500 560
75
90
110
132
160
110
137
165
198
247
144
180
216
260
325
(122)
(153)
(183)
(221)
(276)
-
-
-
-
110
137
165
198
247
37
50
57
72
5.5
7.5
11
15
18.5
5.5
7.5
11
15
18.5
8.8
12.2
17.5
22.1
26.7
11.5
16
23
29
35
(9.8)
(13)
(19)
(24)
(30)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
11.5
16
20
27
32
8.1
10
16
19
24
*7
Forced air cooling
3.5
6.5
6.5
7.5
7.5
185
220
250
280
275
329
366
416
361
432
481
547
(306)
(367)
(408)
(464)
120% 60s, 150% 3s
(inverse-time characteristics)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
-
-
-
-
-
275
329
366
416
Open type (IP00)
Forced air cooling
72
110
110
175
175
Rating
22
30
37
45
22
30
37
45
32.8
43.4
53.3
64.8 80.8
43
57
70
85
(36)
(48)
(60)
(72)
41
52
65
79
31
41
50
61
Open type (IP00)
13
13
23
35
315
355
400
450
500
464
520
586
659
733
610
683
770
866
962
(518)
(580)
(654)
(736)
(817)
-
-
-
-
-
464
520
586
659
733
175
260
260
370
370
that of the power supply.
2
55
55
106
(90)
99
74
35
560
833
1094
(929)
-
833
370
7
347