Parameter list

4.2 Parameter list
4.2.1
Parameter list
In the initial setting, only the simple mode parameters are displayed.
Set Pr. 160 User group read selection as required.
To use the inverter under IPM motor control, refer to page 77.
Parameter
Name
User group read
160
selection
REMARKS
⋅ The parameters marked
⋅ The parameters marked with
value) is set in Pr. 77 Parameter write selection.
⋅ Refer to the appendix 2 (page 368) for instruction codes for communication and availability of parameter clear, all clear, and
parameter copy of each parameter.
......... Specifications differ according to the date assembled. Refer to page 378 to check the SERIAL number.
Function
Parameters
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
64
Initial
Value
9999
are the simple mode parameters.
in the table allow their settings to be changed during operation even if "0" (initial
Name
Setting
Range
9999
Only the simple mode parameters can be displayed.
Simple mode and extended mode parameters can be
0
displayed.
Only the parameters registered in the user group can be
1
displayed.
Setting Range
0 to 30%
0 to 120Hz
0 to 120Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600/ 360s
0 to 3600/ 360s
0 to 500/0 to 3600A
0 to 120Hz, 9999
0 to 10s
0 to 30%
0 to 60Hz
0, 1
0 to 400Hz
0 to 3600/360s
0, 2, 4
120 to 400Hz
0 to 1000V, 8888, 9999
Remarks
Minimum
Refer
Initial
Setting
Value
Increments
Page
6/4/3/2/
0.1%
1.5/1%
*1
120/60Hz
0.01Hz
*2
0.01Hz
0Hz
0.01Hz
60Hz
0.01Hz
60Hz
0.01Hz
30Hz
0.01Hz
10Hz
0.1/0.01s
5s/15s
*3
0.1/0.01s
10s/30s
*3
Rated
0.01/0.1A
inverter
current
0.01Hz
3Hz
0.1s
0.5s
0.1%
4/2/1%
*4
0.01Hz
0.5Hz
1
1
0.01Hz
5Hz
0.1/0.01s
0.5s
1
0
120/60Hz
0.01Hz
*2
0.1V
9999
Customer
to
Setting
87
96
96
98
102
102
102
109
109
117
123
123
123
113
100
104
104
136
96
98

Hide quick links: