Operation panel (FR-DU07)

4.1 Operation panel (FR-DU07)
4.1.1

Component of the operation panel (FR-DU07)

To mount the operation panel (FR-DU07) on the enclosure surface, refer to page 32.
(a) Unit indicator
(b) Monitor (4-digit LED)
(c) Setting dial
(d) PU/EXT key
(e) MODE key
(f) SET key
No.
Component
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
60
Name
Hz: Lit to indicate frequency. (Flickers when the set frequency monitor is displayed.)
Unit indicator
A: Lit to indicate current.
V: Lit to indicate voltage.
Shows the frequency, parameter number, etc.
Monitor (4-digit LED)
(To monitor the output power, set frequency and other items, set Pr.52.)
The dial of the Mitsubishi inverters. The setting dial is used to change the frequency and
parameter settings.
Press the setting dial to perform the following operations:
Setting dial
To display a set frequency in the monitor mode
To display the present setting during calibration
To display a fault history number in the faults history mode
Used to switch between the PU and External operation modes.
To use the External operation mode (operation using a separately connected frequency setting
potentiometer and start signal), press this key to light up the EXT indicator.
(Press
PU/EXT key
operation mode. )
PU: PU operation mode
EXT: External operation mode
Used to cancel the PU stop also.
Used to switch among different setting modes.
Pressing
MODE key
Holding this key for 2 seconds locks the operation. The key lock is invalid when Pr.161="0
(initial setting)." (Refer to page 295.)
Used to enter a setting.
If pressed during the
SET key
operation, monitored item
changes as the following:
Monitor indicator
Lit to indicate the monitor mode.
IPM motor control
Lit to indicate IPM motor control.
indicator
Flickers to indicate IPM motor test operation.
PU: Lit to indicate the PU operation mode.
Operation mode
EXT: Lit to indicate the External operation mode. (EXT is lit at power-ON in the initial setting.)
indicator
NET: Lit to indicate the Network operation mode.
PU and EXT: Lit to indicate EXT/PU combined operation mode 1 and 2
FWD: Lit to indicate the forward rotation.
REV: Lit to indicate the reverse rotation.
Rotation direction
Lit: When the forward/reverse operation is being performed.
indicator
Flickers: When the frequency command is not given even if the forward/reverse command is given.
FWD key: Used to give a start command in forward rotation.
FWD key, REV key
REV key: Used to give a start command in reverse rotation.
Used to stop operation commands.
STOP/RESET key
Used to reset a fault when the protective function (fault) is activated.
Description
simultaneously (0.5s), or change the Pr.79 setting to change to the combined
simultaneously changes the operation mode.
Output frequency → Output current → Output voltage
* Energy saving monitor is displayed when the
energy saving monitor is set with Pr. 52.
When the frequency command is lower than the starting frequency.
When the MRS signal is being input.
(g) Monitor indicator
(h) IPM motor control indicator
(i) Operation mode indicator
(j) Rotation direction indicator
(k) FWD key, REV key
(l) STOP/RESET key
*