Mitsubishi Electric FR-F720P-0.75K to 110K Instruction Manual page 39

Fr-f700p series
Hide thumbs Also See for FR-F720P-0.75K to 110K:
Table of Contents

Advertisement

Control circuit specifications
(2) Output signals
Terminal
Terminal
Symbol
Name
A1,
Relay output 1
B1,
(Fault output)
C1
A2,
B2,
Relay output 2
C2
Inverter
RUN
running
Up to
SU
frequency
Overload
OL
warning
Instantaneous
IPF
power failure
Frequency
FU
detection
Open collector
SE
output common
FM
For meter
Analog signal
AM
output
(3) Communication
Terminal
Terminal
Symbol
Name
PU
connector
Inverter
TXD+
transmission
TXD-
terminal
Inverter
RXD+
reception
RXD-
terminal
SG
Earth (Ground)
28
Description
1 changeover contact output indicates that the
inverter's protective function has activated and the
output stopped.
Fault: No conduction between B and C (conduction
between A and C)
Normal: Conduction between B and C (No conduction
between A and C)
1 changeover contact output
Switched low when the inverter output frequency is
equal to or higher than the starting frequency (initial
value 0.5Hz). Switched high during stop or DC
injection brake operation.
Switched low when the output
frequency reaches within the range
of ±10% (initial value) of the set
frequency. Switched high during
acceleration/deceleration and at a
stop.
Switched low when stall prevention is
activated by the stall prevention
function. Switched high when stall
prevention is cancelled.
Switched low when an instantaneous
power failure and under voltage
protections are activated.
Switched low when the inverter
output frequency is equal to or higher
than the preset detected frequency
and high when less than the preset
detected frequency.
Common terminal for terminals RUN, SU, OL, IPF, FU
Select one e.g. output frequency
from monitor items. (Not output
during inverter reset.)
The output signal is proportional to
the magnitude of the corresponding
monitoring item.
To set a full-scale value for
monitoring the output frequency and
the output current, set Pr.56 and
Pr.158.
With the PU connector, communication can be established through RS-485.
(for connection on a 1:1 basis only)
Conforming standard
: EIA-485 (RS-485)
Transmission format
: Multidrop link
Communication speed : 4800 to 38400bps
Overall length
: 500m
With the RS-485 terminals, communication can be established through RS-485.
Conforming standard
: EIA-485 (RS-485)
Transmission format
: Multidrop link
Communication speed : 300 to 38400bps
Overall length
: 500m
Rated Specifications
Contact capacity: 230VAC 0.3A
(Power factor=0.4)
30VDC 0.3A
Permissible load 24VDC
(27VDC maximum) 0.1A
(A voltage drop is 3.4V
maximum when the signal is
ON.)
Low is when the open collector
Alarm code
output transistor is ON
(4bit) output
(conducts).
High is when the transistor is
OFF (does not conduct).
Permissible load current 2mA
1440 pulse/s at 60Hz (general-
Output item:
purpose motor control)
Output
1440 pulse/s at 90Hz (IPM motor
frequency
control with 30K or lower)
(initial setting)
1440 pulse/s at 120Hz (IPM
motor control with 37K or higher)
Output item:
Output signal 0 to 10VDC
Output
Permissible load current 1mA
(load impedance 10kΩ or
frequency
more) Resolution 8 bit
(initial setting)
Description
Refer
to
Page
140
140
140
140
140
140
140
- -- - -- -- -- - -- -- -- - --
-- -- -
157
157
Refer to
Page
224
226

Hide quick links: