Communication operation and setting
Parameter
Parameters Register
41000 to
0 to 999
C2(902)
C3(902)
125(903)
C4(903)
C5(904)
C6(904)
126(905)
C7(905)
C42(934)
C43(934)
C44(935)
C45(935)
Faults history
Register
40501
Fault history 1
40502
Fault history 2
40503
Fault history 3
40504
Fault history 4
40505
Fault history 5
40506
Fault history 6
40507
Fault history 7
40508
Fault history 8
Data
Description
H00
No fault
H10
H11
H12
H20
H21
H22
H30
H31
258
Parameter Name
Refer to the parameter list (page
41999
64) for the parameter names.
Terminal 2 frequency setting
41902
bias (frequency)
Terminal 2 frequency setting
42092
bias (analog value)
Terminal 2 frequency setting
43902
bias (terminal analog value)
Terminal 2 frequency setting
41903
gain (frequency)
Terminal 2 frequency setting
42093
gain (analog value)
Terminal 2 frequency setting
43903
gain (terminal analog value)
Terminal 4 frequency setting
41904
bias (frequency)
Terminal 4 frequency setting
42094
bias (analog value)
Terminal 4 frequency setting
43904
bias (terminal analog value)
Terminal 4 frequency setting
41905
gain (frequency)
Terminal 4 frequency setting
42095
gain (analog value)
Terminal 4 frequency setting
43905
gain (terminal analog value)
41934
PID display bias coefficient
42124
PID display bias analog value
PID display bias analog value
43934
(terminal analog value)
41935
PID display gain coefficient
42125
PID display gain analog value
PID display gain analog value
43935
(terminal analog value)
Definition
Fault code list
Data
Description
H40
H50
OC1
H51
OC2
H52
OC3
H60
OV1
H61
OV2
H70
OV3
H80
THT
H81
THM
H90
Read/Write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/Write
Read/write
Read
Being 2 bytes in length, the data is stored as
Read
"H00
Read
code.
Read
Performing write using the register 40501 batch-
Read
clears the faults history. Set any value as data.
Read
Read
Data
Description
FIN
H91
PTC
IPF
HA0
OPT
UVT
HA1
OP1
ILF
HB0
PE
OLT
HB1
PUE
SOT
HB2
RET
BE
HB3
PE2
GF
HC0
CPU
LF
HC1
CTE
OHT
HC2
P24
Remarks
The parameter number + 41000 is the
register number.
The analog value (%) set to C3 (902) is
read.
The analog value (%) of the voltage (current)
applied to the terminal 2 is read.
The analog value (%) set to C4 (903) is
read.
The analog value (%) of the voltage
(current) applied to the terminal 2 is read.
The analog value (%) set to C6 (904) is
read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
The analog value (%) set to C7 (905) is
read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
The analog value (%) set to C43 (934) is
read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
The analog value (%) set to C45 (935) is
read.
The analog value (%) of the current
(voltage) applied to the terminal 4 is read.
Remarks
". Refer to the lowest 1 byte for the fault
Data
Description
HC4
CDO
HC5
IOH
HC6
SER
HC7
AIE
HE6
PID
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13