Xerox Phaser 6121MFP Service Manual page 88

Multi-function printer
Hide thumbs Also See for Phaser 6121MFP:
Table of Contents

Advertisement

Theory of Operation
Power Supply Fan
Ventilation Fan
Output Tray Fan
2-46
The Power Supply Fan cools the system Power Supply and operates at full-speed,
half-speed, or stopped states.
The Power Supply Fan runs at full-speed for:
A set period of time after the Power Switch is turned On.
A set period of time after exiting Energy Saver mode.
At the start of a print cycle (full-speed rotation after a set period of half-speed
rotation).
The Power Supply Cooling Fan runs at half-speed:
At the end of a print cycle (half-speed rotation following the predetermined
period of time needed for full-speed rotation).
During half-speed rotation under any condition other than above.
The Power Supply Fan stops when:
The system enters the Energy Saver mode.
The Power Switch is turned Off.
The Ventilation Fan cools the system cabinet and operates at full-speed when the
Main Motor is in operation.
The Output Tray Fan cools the Scanner and operates at full-speed, half-speed, or
stopped states according to these conditions:
The Output Tray Fan runs at full-speed:
A set period of time after the Power Switch is turned On.
A set period of time after exiting Energy Saver mode.
At the start of a print cycle (full-speed rotation after a set period of half-speed
rotation).
The Output Tray Fan runs at half-speed:
At the end of a print cycle (half-speed rotation following the predetermined
period of time needed for full-speed rotation).
During standby.
The Output Tray Fan stops when:
During Energy Saver mode.
During firmware upgrade.
Phaser 6121MFP Service Manual