Some commands may also affect the values of other command, for
example if a confi guration label is printed (see
the print direction is reset to ZT, and if an
is executed, the label width (see

Example

Let us assume that we will use an EasyCoder C4 for direct thermal
printing. We will print full width Thermal Top labels in the peel-off
mode without using the label taken sensor. The default communication
setup and character set are acceptable.
Thus, a few setup parameters should be changed in the Direct Mode:
• Density from 10 to 8
• Media feed adjustment from 136 to 110
• Label Taken Sensor from enabled to disabled
Enter the following commands:
Command
D8 ↵
j110 ↵
Intermec EasyCoder ESim v4.00—Programmer's Reference Manual
Chapter 3—Setting Up the Printer
U
R
Reference Point command
q
command) will be changed.
Explanation
CR/LF to start command structure
Set density
Set media feed adjustment for peel-off
operation
and
UP