JB – Disable Top of Form Backup
This command disables automatic top of form backup of the
Description
media.
Syntax
JB
Top of form backup is used in connection with the
Remarks
which makes the printer feed out an extra amount of media after
printing the label, so as to allow the media to be torn or peeled
off properly. It does not work with a cutter.
By default, the media is pulled back before printing the fi rst label
in next batch as to allow the printing to start at the top of the
label, see
The JB command will disable this function, that is any
mand will be ignored, and the printer will stop feeding when
the end of the label becomes aligned with the printhead's dot
line. However, the
be enabled again using a
baclup with a cutter, fi rst send an
command.
Example
JB↵
Intermec EasyCoder ESim v4.00—Programmer's Reference Manual
JF
command.
j
command is kept stored in memory and can
JF
Chapter 7—Commands
command. To disabled top of form
O
command followed by a JB
:Disables top of form backup
j
command,
j
com-