Provided you use the serial interface for communication between printer
1
and host
, you can make the printer return prompts that appear on the
screen, requesting the operator to enter input data, by sending a
command after each power-up. The optional Keyboard Display Unit
automatically sends the
Printer Sends...
UI80,001
Enter Product name:
Enter Model number:
Checked by:
Enter SERIAL#:
100001
Number of labels sets
P1
Copies of each label
1
1
/. The font selected in this example allows uppercase characters only.
Intermec EasyCoder ESim v4.00—Programmer's Reference Manual
Chapter 6—Retrieving and Printing a Form
UI
command at power-up.
Command
↵
UI
FR"TEST"↵
?↵
EASYCODER↵
501SA↵
Dan↵
100000↵
P1↵
2↵
Explanation
CR/LF to start command structure
Enable prompts command (optional)
Printer returns code page status
Retrieve form
Call for variables
Substitute variable V001
Substitute variable V01
Substitute variable V02
Reset, accept, or enter2 counter start
value C0
Prompt
Ignore
Enter P + Quantity of labels
Prompt
Enter number of copies + ↵
UI
27
Need help?
Do you have a question about the EasyCoder C4 and is the answer not in the manual?
Questions and answers