^ee – Immediate Error Report, cont.
Example
Serial
Manual
command
action
US↵
AA↵
Open cover <NAK>11<XOFF>
UV↵
^ee↵
Close cover <XON>1-972600-33,→
P↵
Press
FEED key
Intermec EasyCoder ESim v4.00—Programmer's Reference Manual
Reply on RS232
<ACK>
(Nothing happens)
(Nothing happens)
01,11<CR><LF>
→Base 3.33<CR><LF>
<NAK>01<XOFF>
<XON>
Chapter 7—Commands
Comments
Enable Error Reporting
Command with syntax error
(01)
Manual action to generate error
(11) and wait in position of
error-waiting-recovering.
Command to print product ID
will be queued
Command reports direct all
errors/status
Manual action to release error
11. Command UV will now be
performed.
Command to print, reports
syntax error (01)
Manual action to release error
status
117