Y Serial Port Setup - Intermec EasyCoder C4 Reference Manual

Esim v4.00 for bar code label printer
Hide thumbs Also See for EasyCoder C4:
Table of Contents

Advertisement

Chapter 7—Commands
Y – Serial Port Setup
This command is used to establish the communication
Description
parameters of the serial RS-232 port.
Syntax
Yp
1
Parameters
p
1
p
2
p
3
p
4
After receiving this command, the printer will automatically reset
Remarks
its communication on the serial RS-232 communication port.
There are no such parameters for the USB port.
By default, the printer is set for 9600 baud, no parity, 8 data bits,
1 stop bit.
XON/XOFF handshaking is always used. The printer sends
XOFF when an error occurs. RTS/CTS is not supported
If the current communication setup is not known, it can be
checked by printing a test label (see
Example
Y19,O,7,1↵
112
Intermec EasyCoder ESim v4.00—Programmer's Reference Manual
,p
,p
,p
2
3
4
Baud rate:
19 19,200 baud.
96 9,600 baud.
48 4,800 baud.
24 2,400 baud.
12 1,200 baud.
Parity:
O Odd.
(O is uppercase o character; ASCII 79 dec.).
E Even.
N None.
Number of data bits:
7 7 data bits.
8 8 data bits.
Number of stop bits:
1 1 stop bit.
2 2 stop bits.
Chapter
1).
:Sets 19,200 baud, odd parity,
7 data bits, 1 stop bit