Maximum Frequency - Omron SYSDRIVE RX Series User Manual

High-function general-purpose inverter
Table of Contents

Advertisement

Maximum Frequency

•Set the maximum value of the output frequency.
•The value set here is the maximum value (e.g.,10 V in the range from 0 to 10 V) of the external
analog input (frequency reference).
•The maximum Inverter output voltage from base to maximum frequencies is the voltage set in AVR
voltage selection A082.
•The Inverter cannot output voltage beyond that of the incoming voltage.
Parameter No.
Function name
A004
Maximum frequency
A204
*2nd maximum frequency
A304
*3rd maximum frequency
Related functions
* To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it
on.
Analog Input (FV, FE, FI)
•The Inverter has three types of external analog input terminals.
FV-FC terminal: 0 to 10 V (voltage input)
FI-FC terminal: 4 to 20 mA (current input)
FE-FC terminal: -10 to 10 V (voltage input)
•Below are the settings for this function.
Parameter No.
Function name
A005
FV/FI selection
Output voltage
AVR voltage
selection
(A082)
Base frequency
30 to 400
Data
00: Switches between FV/FI via terminal AT
01: Switches between FV/FE via terminal AT
02: Switches between FV/FREQ adjuster via
terminal AT (Enabled only when 3G3AX-
OP01 is used.)
03: Switches between FI/FREQ adjuster via
terminal AT (Enabled only when 3G3AX-
OP01 is used.)
04: Switches between FE/FREQ adjuster via
terminal AT (Enabled only when 3G3AX-
OP01 is used.)
4-2 Function Mode
Max. frequency
Data
Default setting
60.0
A003, A203, A303, A081, A082
Default setting
Unit
Hz
Unit
00
4-12
4