Function name
No.
Selection of non-stop
1334h
function at momentary
power interruption
Starting voltage of
non-stop function at
1335h
momentary power
interruption
Starting deceleration level
of non-stop function at
1336h
momentary power
interruption
Deceleration time of
1337h
non-stop function at
momentary power
1338h
interruption
Deceleration starting width
of non-stop function at
1339h
momentary power
interruption
Proportional gain setting of
non-stop function at
133Ah
momentary power
interruption
Integral time setting of
non-stop function at
133Bh
momentary power
interruption
133Ch
to
Not used
133Eh
Window comparator FV
133Fh
upper limit level
Window comparator FV
1340h
lower limit level
Window comparator FV
1341h
hysteresis width
Window comparator FI
1342h
upper limit level
Function
R/W
Monitor and setting parameters
code
0: Disabled
1: Deceleration stop
2: Momentary power interruption non-
b050
R/W
stop (without recovery)
3: Momentary power interruption non-
stop (with recovery)
b051
R/W
0 to 10000
b052
R/W
0 to 10000
b053
R/W
(HIGH)
0 to 360000
b053
R/W
(LOW)
b054
R/W
0 to 1000
b055
R/W
0 to 255
b056
R/W
0 to 65535
Set an upper limit level.
Setting range: 0 to 100
b060
R/W
Lower limit: Lower limit level + Hysteresis
width × 2
Set a lower limit level.
Setting range: 0 to 100
b061
R/W
Upper limit: Upper limit level - Hysteresis
width × 2
Set a hysteresis width for the upper and
lower limit levels.
b062
R/W
Setting range: 0 to 10
Upper limit: (Upper limit level - Lower limit
level) × 2
Set an upper limit level.
Setting range: 0 to 100
b063
R/W
Lower limit: Lower limit level + Hysteresis
width × 2
4-4 Communication Function
Resolution
0.1 [V]
4
0.1 [V]
0.01 [s]
0.01 [Hz]
0.01
0.001 [s]
1 [%]
1 [%]
1 [%]
1 [%]
4-190