Parameter
Function name
No.
Multi-function output
C021
terminal
P1 selection
Multi-function output
C022
terminal P2 selection
Multi-function output
C023
terminal P3 selection
Multi-function output
C024
terminal P4 selection
Multi-function output
C025
terminal P5 selection
Relay output (MA,
C026
MB) function
selection
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
00: RUN (signal during RUN)
01: FA1 (constant speed arrival signal)
02: FA2 (over set frequency arrival signal)
03: OL (overload warning)
04: OD (excessive PID deviation)
05: AL (alarm output)
06: FA3 (set-frequency-only arrival signal)
07: OTQ (overtorque)
08: IP (signal during momentary power interruption)
09: UV (signal during undervoltage)
10: TRQ (torque limit)
11: RNT (RUN time over)
12: ONT (Power ON time over)
13: THM (thermal warning)
19: BRK (brake release)
20: BER (brake error)
21: ZS (0 Hz signal)
22: DSE (excessive speed deviation)
23: POK (position ready)
24: FA4 (set frequency exceeded 2)
25: FA5 (set frequency only 2)
26: OL2 (overload warning 2)
27: FVDc (analog FV disconnection detection)
28: FIDc (analog FI disconnection detection)
29: FEDc (analog FE disconnection detection)
31: FBV (PID FB status output)
32: NDc (network error)
33: LOG1 (logic operation output 1)
34: LOG2 (logic operation output 2)
35: LOG3 (logic operation output 3)
36: LOG4 (logic operation output 4)
37: LOG5 (logic operation output 5)
38: LOG6 (logic operation output 6)
39: WAC (capacitor life warning signal)
40: WAF (cooling fan life warning signal)
41: FR (starting contact signal)
42: OHF (fin overheat warning)
43: LOC (light load detection signal)
44: Not used
45: Not used
46: Not used
47: Not used
48: Not used
49: Not used
50: IRDY (operation ready signal)
51: FWR (forward run signal)
52: RVR (reverse run signal)
53: MJA (fatal fault signal)
54: WCFV (window comparator FV)
55: WCFI (window comparator FI)
56: WCFE (window comparator FE)
(When C062 is used to select the alarm code
output, the multi-function output terminals P1 to
P3, or P1 to P4 are forcibly changed to AC0 to
AC2 or AC0 to AC3 [Acn 'Alarm code output'],
respectively.)
Appendix-1 Parameter List
Changes during
Default
operation
Unit
setting
Normal b031 = 10
00
01
03
No
Yes
07
40
05
App-24
Page
4-92