Omron SYSDRIVE RX Series User Manual page 367

High-function general-purpose inverter
Table of Contents

Advertisement

External resistor type (3G3AX-RBU23/-RBU24/-RBU42/-RBU43)
Applicable voltage class
Model
3G3AX-RBU23
Continuous
6 Ω min.
operation
Short-time/
operation
4 Ω min.
Allowable
1/5
operation cycle/
2 min
Continuous ON
time
Operating voltage ON/
ON: 362.5 ± 5 V
OFF
OFF: 355 ± 5 V
Operation indication
LED ON (Lit)
Maximum number of
units operating in
2 units max.
parallel
Built-in relay specifications
Internal power
module overheat
protection
Ambient
-10°C to 50°C
temperature
Ambient storage
-20°C to 65°C (short-time temperature during transport)
temperature
Humidity
20% to 90% (with no condensation)
Vibration
4.9 m/s
Location
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Paint color
Munselle 5Y7/1 (cooling fan: aluminum ground color)
*1 When using a braking resistor (model 3G3AX-RAB/-RBB/-RBC) for a 400-V-class regenerative braking unit,
connect two of the same size braking resistors in series.
Damage may occur to a 400-V-class regenerative braking unit if operated with only one braking resistor con-
nected.
*2 Set up using DIP switch.
3-phase 200-V class
3G3AX-RBU24
4 Ω min.
2 Ω min.
1/5
2 min
Cooling fin temperature
Relay operates at approximately 100°C or higher.
• Rating of contact: 240 V AC 3 A (R load)
36 V DC 2 A (R load)
• Minimum load:
5 V DC 50 mA (R load)
2
(0.5G) 10 to 55 Hz
3-phase 400-V class
3G3AX-RBU42
3G3AX-RBU43
24 Ω min.
12 Ω min.
10 Ω min.
6 Ω min.
1/10
1/5
10 s
2 min
ON: 725 ± 5 V
OFF: 710 ± 5 V
7-3 Options
7
7-18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents