4-1 Monitor Mode

4Functions

4-1 Monitor Mode

Output Frequency Monitor [d001]
Displays the output frequency of the Inverter. During stop, "0.00" is displayed.
The data LED indicator "Hz" lights up while the d001 setting is displayed.
(Display)
0.00 to 99.99
4
100.0 to 400.0
Note: When the frequency reference is set using the Digital Operator, the output frequency can be
Output Current Monitor [d002]
Displays the output current value of the Inverter. During stop, "0.00" is displayed.
The data LED indicator "A" lights up while the d002 setting is displayed.
(Display)
0.0 to 999.9: Displays in increments of 0.1 A.
Rotation Direction Monitor [d003]
Displays the RUN direction of the Inverter.
The RUN LED indicator lights up during forward/reverse rotation.
(Display)
F : Forward
o : Stop
r : Reverse
PID Feedback Value Monitor [d004]
When "Enabled" (01) or "Reverse output enabled" (02) is selected in PID selection A071, the PID
feedback value can be monitored.
Gain conversion is enabled with PID scale A075.
"d004 display" = "PID feedback value (%)" × "PID scale (A075)"
(Display)
0.00 to 99.99
100.0 to 999.9
1000 to 9999
⎡100 to ⎡999
4-1
: Displays in increments of 0.01 Hz.
: Displays in increments of 0.1 Hz.
changed with the Increment/Decrement key during operation only.
The frequency setting changed with this monitor will be reflected in frequency reference F001.
Pressing the Enter key overwrites the currently selected frequency reference.
: Displays in increments of 0.01.
: Displays in increments of 0.1.
: Displays in increments of 1.
: Displays in increments of 10.
(A075): 0.01 to 99.99 (Can be set in increments of 0.01.)