Specifications of Multi-function Output Terminals P1 to P5
•Below are the specifications of multi-function output terminals P1 to P5.
Inside the Inverter
C031 to C035 set values
00
(NO contact)
01
(NC contact)
Specifications of the Relay Output Terminals
•The relay output terminals have an SPDT contact configuration. Below is its operation.
Inside the Inverter
(Example) When the relay output terminals are used for alarm
C036
Inverter
set
Power
status
values
Abnormal
ON
00
Normal
OFF
Abnormal
ON
01
Normal
(Default)
OFF
P5
PC
Power
Output
supply
status
ON
OFF
OFF
ON
OFF
OFF
MC
Output terminal
Resistance load
status
MA-MC
MB-MC
MA-MC
Closed
Open
Open
Closed
MB-MC
Open
Closed
Open
Closed
Closed
Open
Open
Closed
P1
Electrical characteristics
ON
Between each terminal and PC
Voltage drop 4 V max. at power-on
Max. allowable voltage: 27 V DC
Max. allowable current: 50 mA
ON
MA
MB
(Default value: C036 = 01)
Max.
250 V AC, 2 A
contact
30 V DC, 8 A
capacity
Min.
100 V AC, 10 mA
contact
capacity
Max.
250 V AC, 1 A
contact
30 V DC, 1 A
capacity
Min.
100 V AC, 10 mA
contact
capacity
4-2 Function Mode
Inductive load
250 V AC, 0.2 A
30 V DC, 0.6 A
5 V DC, 100 mA
250 V AC, 0.2 A
30 V DC, 0.2 A
5 V DC, 100 mA
4-94
4