Omron SYSDRIVE RX Series User Manual page 43

High-function general-purpose inverter
Table of Contents

Advertisement

Power cable
Motor
Applicable
output
Inverter
R, S, T, U, V,
(kW)
model
W, +1, P/+2,
3G3RX-
0.4
A4004
3G3RX-
0.75
A4007
3G3RX-
1.5
A4015
3G3RX-
2.2
A4022
3G3RX-
3.7
A4037
3G3RX-
5.5
A4055
3G3RX-
7.5
A4075
3G3RX-
11
A4110
3G3RX-
15
A4150
3G3RX-
18.5
A4185
3G3RX-
22
A4220
3G3RX-
30
A4300
3G3RX-
37
A4370
3G3RX-
45
A4450
3G3RX-
55
A4550
3G3RX-
75
(38 × 2)
A4750
3G3RX-
90
(38 × 2)
A4900
3G3RX-
110
(60 × 2)
A411K
3G3RX-
132
A413K
*1. When the cable is connected without using the crimp terminal (bare wires), use the square washer included
with the product.
Note: The cable size is based on the HIV cable (75°C heat resistance).
External
2
(mm
)
Ground
braking resistor
cable
between +1
2
(mm
)
and RB (mm
N/-
1.25
1.25
1.25
1.25
1.25
1.25
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
8
8
14
14
14
14
14
14
22
22
38
22
38
22
60
30
100
38
100
38
150
60
80 × 2
80
Terminal
Crimp
screw
terminal
size
2
)
M4
1.25-4
M4
1.25-4
2
M4
2-4
2
M4
2-4
2
M4
2-4
M5
R2-5
M5
3.5-5
M6
R5.5-6
8
M6
8-6
M6
14-6
M6
14-6
-
M6
22-6
*1
M8
38-8
*1
M8
38-8
*1
M8
R60-8
*1
M10
100-10
*1
M10
100-10
*1
M10
150-10
*1
M10
80-10
2-2 Wiring
Applicable
Tightening
device
torque
Earth leakage
N•m
breaker (ELB)
1.2
5 A
(max.1.8)
1.2
5 A
(max.1.8)
1.2
10 A
(max.1.8)
1.2
10 A
(max.1.8)
1.2
15 A
(max.1.8)
2.4
30 A
(max. 4.0)
2.4
30 A
(max. 4.0)
4.5
50 A
(max. 4.4)
4.5
60 A
(max. 4.9)
4.5
60 A
(max. 4.9)
4.5
75 A
(max. 4.9)
4.5
100 A
(max. 4.9)
8.1
100 A
(max. 20.0)
8.1
150 A
(max. 20.0)
8.1
175 A
(max. 20.0)
20.0
225 A
(max. 22.0)
20.0
225 A
(max. 22.0)
20.0
350 A
(max. 35.0)
20.0
350 A
(max. 35.0)
2-20
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents