Omron SYSDRIVE RX Series User Manual page 408

High-function general-purpose inverter
Table of Contents

Advertisement

Appendix-1 Parameter List
Parameter
Function name
No.
b031
Soft lock selection
RUN time/Power ON
b034
time setting
Rotation direction
b035
limit selection
Reduced voltage
b036
startup selection
b037
Display selection
Initial screen
b038
selection
User parameter
b039
automatic setting
function selection
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
App-15
Monitor or data range
00: Data other than b031 cannot be changed
when terminal SFT is ON.
01: Data other than b031 and the specified
frequency parameter cannot be changed
when terminal SFT is ON.
02: Data other than b031 cannot be
changed.
03: Data other than b031 and the specified
frequency parameter cannot be
changed.
10: Data can be changed during RUN.
0. to 9999. (0 to 99990)
1000 to 6553 (100000 to 655300)
00: Forward and Reverse are enabled
01: Only Forward is enabled.
02: Only Reverse is enabled.
0 (Reduced voltage startup time: small) to
255 (Reduced voltage startup time: large)
00: Complete display
01: Individual display of functions
02: User setting
03: Data comparison display
04: Basic display
00: Screen when the Enter key was pressed
last
01: d001
02: d002
03: d003
04: d007
05: F001
00: Disabled
01: Enabled
Changes during
Default
operation
Unit
setting
Normal b031 = 10
01
No
Yes
0.
No
Yes
h
00
No
No
6
No
Yes
04
No
Yes
01
No
Yes
00
No
Yes
Page
4-51
4-52
4-52
4-53
4-53
4-56
4-57