3-7 Parameter List
Parameter
Function name
No.
H050
PI proportional gain
* 2nd PI proportional
H250
gain
H051
PI integral gain
3
H251 *2nd PI integral gain
H052
P proportional gain
*2nd P proportional
H252
gain
H060 Limit at 0 Hz
H260 * 2nd limit at 0 Hz
Boost amount at SLV
H061
startup, 0 Hz
* 2nd boost amount
H261
at SLV startup, 0 Hz
For PI proportional
H070
gain switching
For PI integral gain
H071
switching
For P proportional
H072
gain switching
H073 Gain switching time
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
3-53
Monitor or data range
0.0 to 999.9
1000.
0.0 to 999.9
1000.
0.01 to 10.00
0.0 to 100.0
0. to 50.
0.0 to 999.9
1000.
0.0 to 999.9
1000.
0.00 to 10.00
0. to 9999.
Changes during
Default
operation
Unit
setting
Normal b031 = 10
100.0
Yes
Yes
100.0
100.0
Yes
Yes
100.0
1.00
Yes
Yes
1.00
100.0
Yes
Yes
%
100.0
50.
Yes
Yes
%
50.
100.0
Yes
Yes
100.0
Yes
Yes
1.00
Yes
Yes
100.
Yes
Yes
ms