4-4 Communication Function
Register
No.
1279h
2-step acceleration
frequency
127Ah
127Bh
2-step deceleration
frequency
127Ch
4
Acceleration pattern
127Dh
selection
Deceleration pattern
127Eh
selection
127Fh
Not used
1280h
Not used
1281h
FI start frequency
1282h
1283h
FI end frequency
1284h
1285h
FI start ratio
1286h
FI end ratio
1287h
FI start selection
1288h
to
Not used
128Ch
128Dh
FE start frequency
128Eh
128Fh
FE end frequency
1290h
1291h
FE start ratio
1292h
FE end ratio
4-185
Function
Function name
code
A095
(HIGH)
A095
(LOW)
A096
(HIGH)
A096
(LOW)
A097
A098
A101
(HIGH)
A101
(LOW)
A102
(HIGH)
A102
(LOW)
A103
A104
A105
A111
(HIGH)
A111
(LOW)
A112
(HIGH)
A112
(LOW)
A113
A114
R/W
Monitor and setting parameters
R/W
0 to 40000
R/W
R/W
0 to 40000
R/W
0: Line
1: S-shape curve
R/W
2: U-shape curve
3: Inverted U-shape curve
4: EL-S-shape curve
0: Line
1: S-shape curve
R/W
2: U-shape curve
3: Inverted U-shape curve
4: EL-S-shape curve
R/W
0 to 40000
R/W
R/W
0 to 40000
R/W
R/W
O to FI end ratio
R/W
FI start ratio to 100
0: External start frequency
R/W
1: 0 Hz
R/W
-40000 to 40000
R/W
R/W
-40000 to 40000
R/W
R/W
-100 to FE end ratio
R/W
FE start ratio to 100
Resolution
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]